TYPE
H2-H2S-H2SF – DOUBLE REDUCTION HELICAL GEAR BOXES
DOUBLE
REDUCTION UNITS - PARALLEL SHAFTS MECHANICAL AND THERMAL
CAPACITIES KW
MECHANICAL
CAPACITIES (kW)
Nominal
Ratio
Input
Speed
rpm
Nominal
Output
Speed
rpm
Unit Size
140
160
180
200
225
250
280
315
355
400
450
500
560
630
710
5.6
1500
1000
750
268
179
134
82.1
55.1
41.3
124
82.7
62.1
156
104
78.1
213
142
107
310
207
156
383
274
223
677
452
339
905
605
455
1148
766
575
1428
1073
872
2328*
1635
1334
3630
2050
1890
4630
3290
2720
-
4290
3290
-
6290
5450
6.2
1500
1000
750
242
161
121
76.6
51.0
38.3
117
78.0
58.6
148
98.6
74.0
199
132
99.4
283
190
142
420
314
235
618
413
310
822
550
422
1055
722
589
1314
993
810
2131*
1479
1210
2970
1880
1740
4420
3000
2490
-
3980
3050
6.86
1500
1000
750
219
146
109
76.6
51.0
38.3
117
78.0
58.6
148
98.6
74.0
199
132
99.4
273
182
140
400
300
224
592
395
299
785
525
422
991
722
589
1314
993
810
2007*
1479
1210
2700
1860
1700
4010
2720
2180
-
3770
2860
7.59
1500
1000
750
198
132
98.8
76.6
51.0
38.3
108
74.8
53.8
143
99.1
71.4
189
126
94.7
248
166
127
381
270
204
539
360
272
730
498
407
896
652
533
1241
933
762
1831*
1385
108626
2640
1800
1650
3700
2520
2120
-
3720
2820
8.4
1500
1000
750
179
119
89.3
66.3
44.2
33.1
97.6
65.1
48.8
131
87.6
65.7
177
120
97.4
247
181
140
333
260
202
498
365
287
622
468
380
913
667
544
1138
871
714
1676*
1323
1107
2610
1760
1610
3680
2550
2180
-
3080
2450
9.3
1500
1000
750
161
108
80.7
62.2
41.5
31.0
91.4
60.9
45.7
119
79.3
59.5
162
113
89.9
226
155
127
323
247
187
458
333
261
601
439
350
834
621
503
1045
799
669
1609
1198
1010
2600
1740
1460
3620
2470
2130
-
3060
2440
10.3
1500
1000
750
146
97.1
72.8
53.9
35.9
27.0
83.1
55.4
41.6
113
75.2
56.4
151
101
80.0
212
149
117
293
235
180
394
307
231
529
420
321
707
531
400
917
719
604
1379
1083
910
2450
1700
1360
3120
2350
2020
-
3140
2450
11.4
1500
1000
750
132
87.7
65.8
50.6
33.8
25.3
73.2
48.9
36.6
105
69.7
52.2
137
97.4
76.1
187
133
101
280
204
155
408
283
212
519
376
282
684
524
407
881
694
579
1376
1063
860
2200
1480
1140
2870
2040
1700
REFER
TO
AGNEE
For capacities
higher than above - refer to AGNEE. Nominal ratios are shown.
Interpolate for other input speeds. A case baffle is fitted
where rating is shown in color. * Forced lubrication system
required for Vertical Units.
THERMAL
CAPACITIES (kW)
Nominal
Ratio
Input
Speed
rpm
Unit Size
140
160
180
200
225
250
280
315
355
400
450
500
560
630
710
Units without Fan Cooling (Horizontal)
5.60
to
11.4
1500
1000
750
28.8
27.2
27.0
35.8
34.2
33.1
45.7
44.2
43.1
82
82
76
102
100
96
125
121
115
160
156
150
220
220
203
300
300
278
388
388
359
480
480
444
495
490
480
615
610
600
-
760
750
-
990
970
12.6
to
25.6
1500
1000
750
27.8
27.1
26.1
33.8
32.2
31.1
43.6
42.2
41.1
77
81
76
97
97
82
120
115
111
156
151
148
196
193
185
250
250
232
324
324
299
382
382
353
475
470
460
595
590
580
-
730
720
-
960
950
Units with Fan Cooling (Horizontal)
5.60
to
11.4
1500
1000
750
76.5
65.1
57.7
95.7
81.2
72.0
127
108
96.2
153
130
116
186
169
149
254
205
197
352
284
272
460
370
355
699
563
540
986
795
762
1323
1245
1043
1080
860
740
1350
1070
920
-
1650
1450
-
1980
1820
12.6
to
25.6
1500
1000
750
71.7
60.9
52.0
95.7
75.1
64.2
119
102
85.7
143
122
104
180
150
131
217
186
171
280
247
219
365
319
279
555
447
427
782
630
605
1017
956
800
1040
830
720
1300
1040
900
-
1250
1090
-
1470
1300
Full Load
Efficiency - 98% (approx.)
TYPE
H2-H2S-H2SF
DOUBLE
REDUCTION UNITS - PARALLEL SHAFTS MECHANICAL AND THERMAL
CAPACITIES KW
MECHANICAL
CAPACITIES (kW)
Nominal
Ratio
Input
Speed
rpm
Nominal
Output
Speed
rpm
Unit Size
140
160
180
200
225
250
280
315
355
400
450
500
560
630
710
12.6
1500
1000
750
119
79.4
59.5
43.5
29.1
21.8
64.5
43.0
32.8
92.5
61.5
46.1
123
86.9
64.7
171
125
94.0
264
177
137
367
253
188
468
339
256
639
496
379
804
632
527
1252
950
756
1900
1255
980
2680
1810
1615
14.0
1500
1000
750
107
71.4
53.6
40.2
26.9
20.2
52.7
35.1
26.4
84.0
56.0
42.0
112
79.0
61.9
160
116
90.4
243
171
130
322
229
175
443
311
246
598
400
301
734
572
473
1097
861
723
1800
1250
935
2520
1770
1330
15.4
1500
1000
750
97.4
64.9
48.7
35.1
23.8
17.6
51.3
34.5
25.7
77.7
51.7
38.9
92.9
61.1
45.7
140
82.7
69.2
200
129
98.6
265
175
130
393
264
198
511
335
251
692
501
372
1045
690
515
1600
1060
830
2260
1540
1240
17.1
1500
1000
750
87.7
58.5
39.7
32.2
21.5
16.1
47.5
31.7
23.8
68.3
45.5
34.1
91.7
61.1
45.7
133
82.7
66.8
200
129
98.6
266
175
130
395
264
198
487
326
245
628
494
372
968
691
513
1480
980
760
2080
1390
1060
18.9
1500
1000
750
79.4
52.9
39.7
28.7
19.1
14.4
42.8
28.5
21.4
61.5
41.0
30.7
72.2
47.6
35.5
108
70.6
53.0
152
100
74.5
218
144
107
310
204
152
433
283
213
590
389
290
870
563
427
1340
900
730
1900
1280
1020
20.9
1500
1000
750
71.8
47.8
35.9
24.8
16.6
12.4
39.8
26.6
19.9
54.1
36.0
27.0
65.2
46.5
36.1
87.8
61.0
45.8
126
87.5
65.7
186
132
103
253
181
142
357
252
189
501
334
252
739
540
422
1230
830
700
1840
1230
970
23.2
1500
1000
750
64.7
43.1
32.3
22.3
14.9
11.2
33.0
22.0
16.5
48.7
32.5
24.4
59.7
42.5
32.6
80.2
54.7
41.1
114
77.0
57.8
170
121
94.8
235
167
130
328
227
171
452
303
228
700
499
391
25.6
1500
1000
750
58.6
39.1
29.3
17.4
11.6
8.7
26.6
17.4
13.0
37.1
24.8
20.4
49.0
34.9
27.3
69.7
49.7
38.9
95.4
67.9
53.2
132
94.2
73.8
185
132
103
271
193
151
397
282
221
565
402
314
For capacities
higher than above - refer to AGNEE. Nominal ratios are shown.
Interpolate for other input speeds.